PLANET SUPRA is an emulsion resin paint made from ultra-electrolyzed water, acryl silicon resin and hyperfine spherical silica. This emulsion results in a reflective and insulating agent reflecting up to 94.6% of solar rays and minimizing heat conduction. (as per JIS R 3106:1998) U-value, R-value, K-value are not applicable to this paint as it is a radiant barrier.

1. Technical Information Ingredients

a) Silica beads

b) Titanium oxide

c) Acryl silicon emulsion

2. Characteristics

a) Reflection rate

  • 94.6%-Near-infrared rays area
  • 92.3%-All wavelength band area
  • 90.4%-Visible ray area

b) U-value (thermal conductivity)

  • 0.14W/mk c) Volume per gram: 0.65 cubic centimeters

d) Non flammable e) Water-based

f) No toxic agent

g) 32 colors

3. Surfaces that can be painted

a) Metal

b) Concrete

c) Slate

d) Wood

e) Cloth

4. Life span of the product

10 years. Companies Warranty 24 months

5. Packing, coverage area & Painting Technique

a) Coverage area: 40u

b) 10kg ( around 15 liters) per 1 can

c) 5 -10% dilution water

d) Brush, roller, spray

6. Drying and hardening time

a) Dry to touch time: 30-40 min

b) Half curing time: 8-12 hours

c) Full curing time: 2 days

7. Thermal barrier performance

Reduction of temperature on buildings from 5 to 7.. Reduction on steam pipes & heat generating equipment20 to 30.

8. Saving on air conditioning cost and electricity load

Reduction in Electric Power Load 25 -30%


PLANET SUPRA CASE STUDIES

PLANET SUPRA delivers what it promises.
Outstanding performance of our product is the result of tedious work and innovative research of Japanese scientists.
Please refer to various real-life test description and results in order to see it for yourself!
These test results prove that PLANET SUPRA helps to reduce energy consumption anywhere from 25% to almost 40%.

Case Study: Carrefour
Bangkok, Thailand

Planet Supra applied to the warehouse rooftop resulted in an over 30°C reduction on the exterior roof surface temperature and an approximate reduction of 5 degrees Celsius in the interior ambient temperature.

Click to download case study »

Case Study: Marriott Hotel
Islamabad, Pakistan

Results: On average interior roof and wall temperatures decreased by 5C to 10C after Planet Supra was applied to the mobile staff accommodations.


Click to enlarge chart

Case Study: Four Seasons Hotel
Bangkok, Thailand

The hotel’s engineering staff tested Planet Supra by painting panels on one of their boilers and hot water pipes.

Results: Planet Supra’s insulating properties maintained constant hot water temperature while reducing the surface temperature of the pipes by 10C, resulting in both improved working conditions and effective cost savings.

Click to enlarge chart